17600 – System Data
System data consists of 8 bytes. The first byte has the current alarm contact settings. Each
bit corresponds to a contact. Bit 0 (lsb) is the bit for the Power Supply 1 alarm, and bit 7
(msb) is the bit for the 'any' alarm. The next two bytes are for the installed card inventory.
A '0' bit means the card is installed and a '1' bit means the card is removed. The other bytes
are for internal use.
17601:17616 – Card Data
Each I/O card in the VxRouter has an associated TCP port. Card 1 uses port 17601, card 2
uses 17602, and so on. The data is formatted as follows:
15 bytes, internal use
1 byte, card type
0xff missing
0x00 upstream
0x01 downstream
SFP data, 256 bytes per SFP, 20 SFPs per card
128 bytes, SFP ID data
128 bytes, SFP diagnostic data
Nov 3, 2014 Router Interfaces: VX160 11/25
Table 2: VX160 System Data
Alarms Inventory
Byte Byte Byte
Bit 0 1 2
0 Alarm 1 Card 1 Card 9
1 Alarm 2 Card 2 Card 10
2 Alarm 3 Card 3 Card 11
3 Alarm 4 Card 4 Card 12
4 Alarm 5 Card 5 Card 13
5 Alarm 6 Card 6 Card 14
6 Alarm 7 Card 7 Card 15
7 Alarm 8 Card 8 Card 16