17600 – System Data
System data consists of 6 bytes. The first byte has the current alarm contact settings. Each
bit corresponds to a contact. Bit 0 (lsb) is the bit for the Power Supply alarm, and bit 3 is
the bit for the 'any' alarm. The next byte is for the installed card inventory. A '0' bit means
the card is installed and a '1' bit means the card is removed. The other bytes are for
internal use.
17601:17603 – Card Data
Each I/O card in the router has an associated TCP port. Card 1 uses port 17601, card 2 uses
17602, and so on. The data is formatted as follows:
6 bytes, internal use
1 byte, card type
0xff missing
0x02 normal
0x05 reclocked
SFP data, 256 bytes per SFP, 16 SFPs per card
128 bytes, SFP ID data
128 bytes, SFP diagnostic data
Nov 3, 2014 Router Interfaces: MX48 19/25
Table 6: MX48 System Data
Alarms Inventory
Byte Byte
Bit 0 1
0 Alarm 1 Card 1
1 Alarm 2 Card 2
2 Alarm 3 Card 3
3 Alarm 4
4
5
6
7